Cables2D
Cable with multiple concentrated loads
Select polygonal, parabolic, or catenary cable models and reject compression, slack, and invalid support conditions.
Open the complete lessonInteractive engineering simulation
Cable with Multiple Concentrated Loads
Create a polygonal funicular cable and inspect the force in every straight segment.
Tension only
Model distinction: point loads create straight polygonal segments; load uniform per horizontal metre creates a parabola; self-weight uniform per cable metre creates a catenary. These models are never silently substituted for one another.
The prescribed sag is measured below the support chord at the first load location, x=10.00 m.
Horizontal component H
28.00 kN
Maximum tension
32.25 kN
Left vertical component
14.00 kN
Right vertical component
16.00 kN
remains constant through every segment, while changes with segment slope. A negative free-support reaction is reported as a hold-down requirement rather than accepted silently.
Model scope and verification